COMPLAINT DETAILS |
|
|
Complaint Date |
: |
2025-02-06 |
Complaint Number |
: |
15990 |
Complaint Registered By |
: |
2004 (P V SATHISH) |
Complaint Category |
: |
COMPLAINT |
Complaint Type |
: |
TEM.CONTROLLER / PLC FAILURE |
Product Name |
: |
DRYER |
Model |
: |
2KD |
Model Number |
: |
2KDCc 040 |
Purchased Through |
: |
GEM EQUIPMENTS PRIVATE LIMITED |
MC/SL. No |
: |
04391/08/2011 |
Warranty Status |
: |
No |
Customer Name |
|
Aqua sub engineering |
Address |
: |
Unit 1, Tudiyalur, Coimbatore -641034 |
Contact Person Name |
: |
Suryaprakash |
Phone No. |
: |
9994924451 |
Cell No. |
|
9994924451 |
E-Mail ID |
|
vansat88@gmail.com |
Fax No. |
|
fax |
Engineer Allotted |
: |
2004 () |
Complaint Attending Date |
: |
2025-02-08 14:47:43 |
Complaint Closing Date |
: |
2025-02-08 14:49:45 |
Status |
: |
Completed |
Complaint Registered time |
: |
2025-02-06 13:23:15 |
Call attending time |
: |
2025-02-08 14:47:43 ( 49 hours ) |
Image |
: |
 |
|
Complete remarks |
: |
in this air dryer temperature control sensor failure and temperature control molfungtionso replace the new one and now air dryer working good condition ok |
|
Call completion time |
: |
2025-02-08 14:49:45 ( 49 hours ) |
|
|
|